Band 
[Volume I.]
Seite
33
JPEG-Download
 

BOILERS FOR STATIONARY ENGINES.

33

Tensile Strength of Single and Double Rivetted Plates.

Cohesive Strength ofPlates.

Breaking Stress in Lbs.per Square Inch.

Strength of Single RivettedJoints, of equal Sectionto the Plates, taken throughthe Line of Rivets.

Strength of Double RivettedJoints, of equal Sectionto the Plates, taken throughthe Line of Rivets.

57.724

45.743

52,352

61.579

36,606

48,821

58,322

43.141

58,286

50.983

43.515

54,594

51.130

40,249

53,879

49,281

44,715

53,869

43.805

37,161

47,062

Mean, 52,485

41,59c

53,633

Area of boiler stays = where A=area of surface of plate

held by one stay, and p and t being the pressure and tenacity re-spectively.

The following value of plates may be fairly assumed with those

of joints:

Plates. ioo

Double Rivetting. 70

Single Rivetting. 56

In a series of experiments by Napier the tensile strength of ironplates averaged from 56,735 to 41,743 lbs. per square inch.

Weight of a Square Foot of Wroitght-iron Plate from to l inch in Thickness .

Thicknessin inches.

Weightin lbs.

Thickness.

Weight.

1

T2

1-25

i + A

21-25

nr

2 '5

TT

22*5

i 1 1

TT-TTT

375

TT + UT

2 3 75

$

5'

5

H

2 5

1 + tV

6-25

5 1 1

26-25

7'5

TT

2 7'5

3 r 1

TT + 'ST

875

11 4. 1

TT ' "5T

28-75

4,

IO*

3°'

1 1 1

? T -3-ff

II *25

T + T5T

31 ' 2 5

5

TT

12-5

TT

32-5

5 1

T 7 T + - 3 T

1375

TT + UT

3375

s

15

T

35

T + TT

16-25

Tr TT2

3 6 ' 2 5

TT

I7-5

1 5

37'5

nr + tt

1875

TS + TT

38 7 5

20 *

I

4 o-

Weight of Angle Iron , in Lbs. per Lineal Foot .

Breadth in inches. IX, iX> iX> 2 , 2 X 2 X, 2 X> 3 . 3 /C> 3 %-

Weight per foot in lbs. I8, 27, 3'3, 3-9, 5, 6-5, 83, io'4, 117, 14.